Huawei S6780-H4Z Switch mainframe (4*subcard slots, with 2pcs AC power modules) PN.02356DTY
Forwarding Performance: 2400 Mpps
Switching Capacity:14.4Tbps /16Tbps
Applicable cards:
XSIC-M26B000
XSIC-X26B000
XSIC-Y26B000
XSIC-L16Q000
XSIC-C10H000
XSIC-C16H000
XSIC-D12B000 (03035KLD)
XSIC-D12B000 (03035KLD-001)
When four XSIC-C16H000 cards are configured, 2000 W AC power modules (110 V AC not supported) or 2200 W DC power modules must be used.
When four other cards of the same type are configured, AC or DC power modules with a power of 1200 W or higher must be used.
When cards of any other combination are configured, evaluate the power of the entire system based on the sum of the chassis power (240 W) and the power of each card and select proper power modules. (Note that the power of a 2000 W AC power module decreases to 900 W when the input voltage is 110 V AC.)
CloudEngine S6780-H series switches are Huawei's next-generation enterprise-class core and aggregation switches that provide 64 x 100GE/32 x 25GE ports and 16 x 400GE optical ports.
CloudEngine S6780-H series switches are Huawei's next-generation 2 U flexible card switches. They provide high-density 100GE and 400GE optical ports, and feature high performance, high reliability, cloud-based management, and intelligent O&M.
| Item | Specification |
| Dimensions without packaging (H x W x D) [mm(in.)] | Basic dimensions (excluding the parts protruding from the body): 88.1 mm x 442.0 mm x 600.0 mm (3.47 in. x 17.40 in. x 23.62 in.) |
| Maximum dimensions (the depth is the distance from ports on the front panel to the parts protruding from the rear panel): 88.1 mm x 442.0 mm x 640.0 mm (3.47 in. x 17.40 in. x 25.20 in.) | |
| Dimensions with packaging (H x W x D) [mm(in.)] | 280.0 mm x 875.0 mm x 665.0 mm (11.02 in. x 34.45 in. x 26.18 in.) |
| Chassis height [U] | 2 U |
| Chassis material | Metal |
| Weight without packaging [kg(lb)] | 20.50 kg (45.19 lb) |
| Weight with packaging [kg(lb)] | 26.82 kg (59.13 lb) |
| Typical power consumption [W] | Configured with four XSIC-C16H000 cards: 940 W |
| Configured with four XSIC-L16Q000 cards: 724 W | |
| Configured with four XSIC-C10H000 cards: 508 W | |
| Configured with four XSIC-D12B000 cards: 621 W | |
| Configured with four XSIC-Y26B000 cards: 423 W | |
| Configured with four XSIC-X26B000 cards: 366 W | |
| Configured with four XSIC-M26B000 cards: 560 W | |
| Typical heat dissipation [BTU/hour] | Configured with four XSIC-C16H000 cards: 3207.37 BTU/hour |
| Configured with four XSIC-L16Q000 cards: 2470.36 BTU/hour | |
| Configured with four XSIC-C10H000 cards: 1733.35 BTU/hour | |
| Configured with four XSIC-D12B000 cards: 2118.91 BTU/hour | |
| Configured with four XSIC-Y26B000 cards: 1433.32 BTU/hour | |
| Configured with four XSIC-X26B000 cards: 1248.83 BTU/hour | |
| Configured with four XSIC-M26B000 cards: 1910.77 BTU/hour | |
| Maximum power consumption [W] | Configured with four XSIC-C16H000 cards: |
| - 1306 W (two 2000 W AC power modules, 220 V input) | |
| Configured with four XSIC-L16Q000 cards: | |
| - 1138 W (two 1200 W AC power modules, 110 V input) | |
| Configured with four XSIC-C10H000 cards: | |
| - 832 W (two 1200 W AC power modules, 110 V input) | |
| Configured with four XSIC-D12B000 cards: | |
| - 1078 W (two 1200 W AC power modules, 110 V input) | |
| Configured with four XSIC-Y26B000 cards: | |
| - 796 W (two 1200 W AC power modules, 110 V input) | |
| Configured with four XSIC-X26B000 cards: | |
| - 788 W (two 1200 W AC power modules, 110 V input) | |
| Configured with four XSIC-M26B000 cards: | |
| - 1023 W (two 1200 W AC power modules, 110 V input) | |
| Maximum heat dissipation [BTU/hour] | Configured with four XSIC-C16H000 cards: |
| - 4456.20 BTU/hour (two 2000 W AC power modules, 220 V input) | |
| Configured with four XSIC-L16Q000 cards: | |
| - 3882.97 BTU/hour (two 1200 W AC power modules, 110 V input) | |
| Configured with four XSIC-C10H000 cards: | |
| - 2838.87 BTU/hour (two 1200 W AC power modules, 110 V input) | |
| Configured with four XSIC-D12B000 cards: | |
| - 3678.24 BTU/hour (two 1200 W AC power modules, 110 V input) | |
| Configured with four XSIC-Y26B000 cards: | |
| - 2716.03 BTU/hour (two 1200 W AC power modules, 110 V input) | |
| Configured with four XSIC-X26B000 cards: | |
| - 2688.73 BTU/hour (two 1200 W AC power modules, 110 V input) | |
| Configured with four XSIC-M26B000 cards: | |
| - 3490.58 BTU/hour (two 1200 W AC power modules, 110 V input) | |
| Static power consumption [W] | Configured with four XSIC-C16H000 cards: 593 W |
| Configured with four XSIC-L16Q000 cards: 539 W | |
| Configured with four XSIC-C10H000 cards: 295 W | |
| Configured with four XSIC-D12B000 cards: 299 W | |
| Configured with four XSIC-Y26B000 cards: 259 W | |
| Configured with four XSIC-X26B000 cards: 259 W | |
| Configured with four XSIC-M26B000 cards: 363 W | |
| MTBF [years] | 48.4 years |
| Availability | > 0.99999 |
| Noise at normal temperature (acoustic power) [dB(A)] | 86.1 dB(A) |
| Noise at normal temperature (acoustic pressure) [dB(A)] | 74.1 dB(A) |
| Number of card slots | 4 |
| Number of power slots | 2 |
| Number of fans modules | 3 |
| Redundant power supply | 1+1 |
| Long-term operating temperature [°C(°F)] | –5°C to +45°C (23°F to 113°F) at an altitude of 0 to 1800 m (0 to 5906 ft.) |
| When the QSFP-100G-ZR4 or QSFP-DD-400G-LR8 optical modules are configured, the operating temperature ranges from –5°C to +40°C (23°F to 104°F). | |
| Restriction on the operating temperature variation rate [°C(°F)] | When the altitude is 1800–5000 m (5906–16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.). |
| Devices cannot start when the temperature is lower than 0°C (32°F). | |
| Storage temperature [°C(°F)] | –40°C to +70°C (–40°F to +158°F) |
| Long-term operating relative humidity [RH] | 5% RH to 95% RH, non-condensing |
| Long-term operating altitude [m(ft.)] | 0–5000 m (0–16404 ft.) |
| Storage altitude [m(ft.)] | 0-5000 m (0-16404 ft.) |
| Power supply mode | Pluggable power supply |
| Rated input voltage [V] | AC input: 100 V AC to 240 V AC; 50/60 Hz |
| High-voltage DC input: 240 V DC | |
| DC input: –48 V DC to –60 V DC | |
| Input voltage range [V] | AC input: 90 V AC to 290 V AC; 45–65 Hz |
| High-voltage DC input: 190 V DC to 290 V DC | |
| DC input: -38.4 V DC to -72 V DC | |
| Maximum input current [A] | The current specifications are related to the pluggable power module. For details, see Pluggable Power Modules. |
| Memory | 8 GB |
| Flash memory | Physical space: 4 GB |
| Console port | RJ45 |
| Eth Management port | RJ45 |
| USB | Supported |
| RTC | Supported |
| RPS input | Not supported |
| Power supply surge protection [kV] | Configured with AC power modules: ±6 kV in differential mode and ±6 kV in common mode |
| Configured with DC power modules: ±2 kV in differential mode and ±4 kV in common mode | |
| Ingress protection level (dustproof/waterproof) | IP20 |
| Types of fans | Pluggable |
| Heat dissipation mode | Air cooling for heat dissipation, intelligent fan speed adjustment |
| Airflow direction | Air intake from front, air exhaustion from rear (front-to-rear) |
| PoE | Not supported |
| Certification | EMC certification |
| Safety certification | |
| Manufacturing certification |