Huawei S5700-10P-PWR-LI-AC switch with 8-port PoE+ 1000BASE-T, 2-port GE SFP, 1 AC power PN #02354037
Forwarding perfomance: 15 Mpps
Switching capacity: 256Gbps
16K MAC address entries
PoE Supported
Applicable power modules:
W0PSA1701 (170 W AC Power Module)
ES5M0PSD1700 (170 W DC Power Module)
Huawei S5700 series switch includes the S5700-LI, S5700S-LI, S5700-LI-BAT, S5710-LI, S5720-LI, S5720S-LI, S5700-SI, S5720-SI, S5730-SI, S5720S-SI, S5720I-SI, S5700-EI, S5710-EI, S5720-EI, S5730S-EI, S5700-HI, S5710-HI, S5720-HI, S5730-HI, S5731-L, S5731S-L, S5731-S, S5731S-S, S5731-H, S5731S-H, S5732-H, S5735-L, S5735-L-I, S5735S-L, S5735S-L-M, S5735-L1, S5735S-L1, S5735-S, S5735-S-I, S5735S-H, S5736-S, and S5735S-S subseries.
The S5700-LI, S5700S-LI, S5700-LI-BAT, S5710-LI, S5720-LI, S5720S-LI, S5731-L, S5731S-L, S5735-L, S5735S-L, S5735-L1, S5735S-L1, and S5735S-L-M switches are Layer 2 switches, and all the other models in this series are Layer 3 switches.
| Item | Description |
| Memory (RAM) | 256 MB |
| Flash | 200 MB |
| Mean time between failures (MTBF) | 36.89 years |
| Mean time to repair (MTTR) | 2 hours |
| Availability | > 0.99999 |
| Service port surge protection | Common mode: ±6 kV |
| Power supply surge protection | ±6 kV in differential mode, ±6 kV in common mode |
| Dimensions (H x W x D) | 43.6 mm x 320.0 mm x 220.0 mm (1.72 in. x 12.6 in. x 8.7 in.) |
| Weight (with packaging) | 2.3 kg (5.07 lb) |
| Stack ports | Not supported |
| RTC | Not supported |
| RPS | Not supported |
| PoE | Supported |
| Rated voltage range | 100 V AC to 240 V AC, 50/60 Hz |
| Maximum voltage range | 90 V AC to 264 V AC, 47 Hz to 63 Hz |
| Maximum power consumption (100% throughput, full PoE) | 142.4 W (system power consumption: 18.4 W, PoE: 124 W) |
| Typical power consumption (30% of traffic load) | 13.51 W |
| Tested according to ATIS standard | |
| EEE enabled | |
| No PoE power consumption | |
| Operating temperature | 0°C to 45°C (32°F to 113°F) at an altitude of 0-1800 m (0-5906 ft.) |
| NOTE: | |
| When the altitude is 1800-5000 m (5906-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.). | |
| Storage temperature | -40°C to +70°C (-40°F to +158°F) |
| Noise under normal temperature (27°C, sound power) | Noise-free (no fans) |
| Relative humidity | 5% to 95%, noncondensing |
| Operating altitude | 0-5000 m (0-16404 ft.) |
| Certification | EMC certification |
| Safety certification | |
| Manufacturing certification | |
| Part number | 2354037 |