Huawei S5720-28X-SI-DC Switch
Review: 5 - "A masterpiece of literature" by , written on May 4, 2006
I really enjoyed this book. It captures the essential challenge people face as they try make sense of their lives and grow to adulthood.

Huawei S5720-28X-SI-DC Switch

  • Brand New Condition
  • Original Box Packed
  • Latest Firmware Version
Image
Available:In Stock
$0.00

Huawei S5720-28X-SI-DC switch with 24-port 1000BASE-T, including 4-port GE SFP combo, 4-port 10GE SFP+, 2 power slots

Forwarding performance: 96Mpps

Switching capacity: 336Gbps

16K MAC address entries

Huawei S5720-SI Flexible Gigabit Ethernet switches that provide resilient, high-density Layer 3 switching for data centers. Features include multiple-terminals, HD video security, and video conferencing applications. Intelligent iStack clustering, 10 Gbit/s upstream ports and IPv6 forwarding enable use as aggregation switches in enterprise campus networks.

Next-generation reliability, security, and energy-saving technologies make S5720-SI Series Switches easy to install and maintain, and an excellent source of low Total Cost of Ownership (TCO).

 

Item Description
Fixed port 24 Ethernet 10/100/1000 ports, 4 of which are dual-purpose 10/100/1000 or SFP

 P series: 4 Gig SFP;X series: 4 10 Gig SFP+

Forwarding performance 96 Mpps
Extended slot NA
MAC address table IEEE 802.1d
16K MAC address entries
MAC address learning and aging
Static, dynamic, and blackhole MAC address entries
Packet filtering based on source MAC addresses
VLAN 4K VLANs
Guest VLAN and voice VLAN
GVRP
MUX VLAN
VLAN assignment based on MAC addresses, protocols, IP subnets, policies, and ports
1:1 and N:1 VLAN Mapping
Wireless AC AP access control, AP domain management, and AP configuration template

 

management

Radio management, unified static configuration, and dynamic centralized management

WLAN basic services, QoS, security, and user management

CAPWAP, Tag/terminal location, and spectrum analysis

Jumbo frame 10K
IP routing Static routes, RIP v1/2, RIPng, OSPF, OSPFv3, IS-IS, IS-ISv6, BGP, BGP4+, ECMP,

 

routing policy

IPv6 features Neighbor Discovery (ND)
Path maximum transmission unit (PMTU)
IPv6 Ping, IPv6 Tracert, and IPv6 Telnet
6 to4 tunnel, ISATAP tunnel, and manually configur ed tunnel
ACLs based on source IPv6 addresses, destination IPv6 addresses, Layer 4 ports

 

or protocol types

Multicast Listener Discovery (MLD) v1/v2 snooping
Multicast forwarding IGMP v1/v2/v3 snooping and IGMP fast leave
Multicast forwarding in a VLAN and multicast replication between VLANs
Multicast load balancing among member ports of a trunk
Controllable multicast
Port-based multicast traffic statistics collection
IGMPv1/v2/v3, Protocol Independent Multicast Sparse Mode (PIM-SM), and Protocol Independent
Multicast Dense Mode (PIM-DM), and Protocol Independent Multicast Source-Specific Multicast (PIM-SSM)
Multicast Source Discovery Protocol (MSDP)
QoS/ACL Rate limitation in the inbound and outbound directions of a port
Packet redirection
Broadcast storm control
Port-based traffic policing and two-rate and three-color CAR
Eight queues per port,Weighted round robin (WRR), deficit round robin (DRR), strict priority (SP), WRR+SP, and DRR+SP queue scheduling algorithms
Weighted random early detection (WRED)
Re-marking of the 802.1p priority and DSCP fields of packets
Packet filtering on Layer 2 to Layer 4, filtering out invalid fr ames based on the source MAC address, destination MAC address, source IP address, destination IP address,

 

TCP/UDP source/destination port number, protocol number, or VLAN

Queue-based rate limitation and shaping on ports
HQoS
Security features Hierarchical user management and password protection
DoS attack defense, ARP attack defense, and ICMP attack defense
Binding of the IP address, MAC address, interface number, and VLAN ID of a user
Port isolation, port security, and sticky MAC
MAC Forced Forwarding (MFF)
Blackhole MAC address entries
Limit on the number of learned MAC addresses
IEEE 802.1x authentication and the limit on the number of users on an interface
AAA authentication, RADIUS authentication, HWTACACS+ authentication, and NAC SSH v2.0
Hypertext Transfer Protocol Secure (HTTPS)
CPU defense; Blacklist and whitelist; MACSec ready
Reliability RRPP ring topology and RRPP multi-instance
Smart Link tree topology and Smart Link multi-instance, providing the millisecond-level protection switchover
SEP
G.8032 Ethernet Ring Protection Switching (ERPS)
STP (IEEE 802.1d), RSTP (IEEE 802.1w), and MSTP (IEEE 802.1s)
BPDU protection, root protection, and loop protection
Super Virtual Fabric (SVF) Working as the parent node to vertically virtualize downlink switches and APs as one

 

device for management

Supports a two-layer client architecture
Management and
Maintenance
Virtual cable test, SNMP v1/v2c/v3, RMON
Network management system (NMS) and Web managemen
System logs and multi-level alarms
802.3az EEE
GVRP
Dying Gasp upon power-off
Interoperability VLAN-Based Spanning Tree (VBST), working with PVST, PVST+, and RPVST
Link-type Negotiation Protocol (LNP), similar with DTP
VLAN Central Management Protocol (VCMP), similar with VTP
Operating environment Operating temperature: 0-1800 m altitude: 0-45℃

 

1800-5000m altitude: The operating temperature reduces by 1oC every time the

altitude increases by 220m.

Relative humidity: 5% to 95% (noncondensing)

Input voltage AC:

Rated voltage range: 100 V to 240 V AC, 50/60 Hz

Maximum voltage range: 90 V to 264 V AC, 50/60 Hz

DC:

Rated voltage range: –48 V to –60 V, DC

Maximum voltage range: –36 V to –72 V, DC

Dimensions (mm) 442 (W) x 420 (D)x 43.6 (H)
Typical power consumption 22.3W
PN. 02350NGU

 

Huawei S5720-28X-SI-DC switch with 24-port 1000BASE-T, including 4-port GE SFP combo, 4-port 10GE SFP+, 2 power slots

Forwarding performance: 96Mpps

Switching capacity: 336Gbps

16K MAC address entries

Huawei S5720-SI Flexible Gigabit Ethernet switches that provide resilient, high-density Layer 3 switching for data centers. Features include multiple-terminals, HD video security, and video conferencing applications. Intelligent iStack clustering, 10 Gbit/s upstream ports and IPv6 forwarding enable use as aggregation switches in enterprise campus networks.

Next-generation reliability, security, and energy-saving technologies make S5720-SI Series Switches easy to install and maintain, and an excellent source of low Total Cost of Ownership (TCO).

 

Item Description
Fixed port 24 Ethernet 10/100/1000 ports, 4 of which are dual-purpose 10/100/1000 or SFP

 P series: 4 Gig SFP;X series: 4 10 Gig SFP+

Forwarding performance 96 Mpps
Extended slot NA
MAC address table IEEE 802.1d
16K MAC address entries
MAC address learning and aging
Static, dynamic, and blackhole MAC address entries
Packet filtering based on source MAC addresses
VLAN 4K VLANs
Guest VLAN and voice VLAN
GVRP
MUX VLAN
VLAN assignment based on MAC addresses, protocols, IP subnets, policies, and ports
1:1 and N:1 VLAN Mapping
Wireless AC AP access control, AP domain management, and AP configuration template

 

management

Radio management, unified static configuration, and dynamic centralized management

WLAN basic services, QoS, security, and user management

CAPWAP, Tag/terminal location, and spectrum analysis

Jumbo frame 10K
IP routing Static routes, RIP v1/2, RIPng, OSPF, OSPFv3, IS-IS, IS-ISv6, BGP, BGP4+, ECMP,

 

routing policy

IPv6 features Neighbor Discovery (ND)
Path maximum transmission unit (PMTU)
IPv6 Ping, IPv6 Tracert, and IPv6 Telnet
6 to4 tunnel, ISATAP tunnel, and manually configur ed tunnel
ACLs based on source IPv6 addresses, destination IPv6 addresses, Layer 4 ports

 

or protocol types

Multicast Listener Discovery (MLD) v1/v2 snooping
Multicast forwarding IGMP v1/v2/v3 snooping and IGMP fast leave
Multicast forwarding in a VLAN and multicast replication between VLANs
Multicast load balancing among member ports of a trunk
Controllable multicast
Port-based multicast traffic statistics collection
IGMPv1/v2/v3, Protocol Independent Multicast Sparse Mode (PIM-SM), and Protocol Independent
Multicast Dense Mode (PIM-DM), and Protocol Independent Multicast Source-Specific Multicast (PIM-SSM)
Multicast Source Discovery Protocol (MSDP)
QoS/ACL Rate limitation in the inbound and outbound directions of a port
Packet redirection
Broadcast storm control
Port-based traffic policing and two-rate and three-color CAR
Eight queues per port,Weighted round robin (WRR), deficit round robin (DRR), strict priority (SP), WRR+SP, and DRR+SP queue scheduling algorithms
Weighted random early detection (WRED)
Re-marking of the 802.1p priority and DSCP fields of packets
Packet filtering on Layer 2 to Layer 4, filtering out invalid fr ames based on the source MAC address, destination MAC address, source IP address, destination IP address,

 

TCP/UDP source/destination port number, protocol number, or VLAN

Queue-based rate limitation and shaping on ports
HQoS
Security features Hierarchical user management and password protection
DoS attack defense, ARP attack defense, and ICMP attack defense
Binding of the IP address, MAC address, interface number, and VLAN ID of a user
Port isolation, port security, and sticky MAC
MAC Forced Forwarding (MFF)
Blackhole MAC address entries
Limit on the number of learned MAC addresses
IEEE 802.1x authentication and the limit on the number of users on an interface
AAA authentication, RADIUS authentication, HWTACACS+ authentication, and NAC SSH v2.0
Hypertext Transfer Protocol Secure (HTTPS)
CPU defense; Blacklist and whitelist; MACSec ready
Reliability RRPP ring topology and RRPP multi-instance
Smart Link tree topology and Smart Link multi-instance, providing the millisecond-level protection switchover
SEP
G.8032 Ethernet Ring Protection Switching (ERPS)
STP (IEEE 802.1d), RSTP (IEEE 802.1w), and MSTP (IEEE 802.1s)
BPDU protection, root protection, and loop protection
Super Virtual Fabric (SVF) Working as the parent node to vertically virtualize downlink switches and APs as one

 

device for management

Supports a two-layer client architecture
Management and
Maintenance
Virtual cable test, SNMP v1/v2c/v3, RMON
Network management system (NMS) and Web managemen
System logs and multi-level alarms
802.3az EEE
GVRP
Dying Gasp upon power-off
Interoperability VLAN-Based Spanning Tree (VBST), working with PVST, PVST+, and RPVST
Link-type Negotiation Protocol (LNP), similar with DTP
VLAN Central Management Protocol (VCMP), similar with VTP
Operating environment Operating temperature: 0-1800 m altitude: 0-45℃

 

1800-5000m altitude: The operating temperature reduces by 1oC every time the

altitude increases by 220m.

Relative humidity: 5% to 95% (noncondensing)

Input voltage AC:

Rated voltage range: 100 V to 240 V AC, 50/60 Hz

Maximum voltage range: 90 V to 264 V AC, 50/60 Hz

DC:

Rated voltage range: –48 V to –60 V, DC

Maximum voltage range: –36 V to –72 V, DC

Dimensions (mm) 442 (W) x 420 (D)x 43.6 (H)
Typical power consumption 22.3W
PN. 02350NGU

 

GLOBAL SHIPPING
XponShop offers you various options of shipping ways:
-EXW SHENZHEN
-Overseas Express which includes shipping by Carriers, by Air Cargo, and Sea Freight.

Cargo Weight/Volume Suggested Shipping Ways Comments
≤ 45KGS By Shipping Carriers (DHL, UPS, FedEx, etc.) Door to door service, fast and convenient.
>45KGS By Air Cargo Door to airport service, more cost-efficient.
1CBM By Sea Freight Large-volume goods, door to seaport service, longer shipping time but cheaper.

XponShop makes the most commonly used trade terms available for your convenience: CNF, CPT, CIF, DDP, etc to ensure global fast and convenient delivery.
Once you confirm your order, you may contact XponShop team for calculating the freight charges and choose the optimal shipping way.
NOTE:
· Shipping may be subject to local taxes or duties; XponShop is not responsible for and has no control over these charges.
· No matter which shipping ways you chose, cargo insurance is highly recommended in case of unpredictable loss.

RETURN POLICY
We aim to deliver products for your appreciation and satisfaction. XponShop return or replacement policy applies only if the product is damaged or incorrectly delivered.
–If you receive a damaged product or it is different from the one requested, you can return or replace it within 7 days of receipt. In such a case, costs shall be borne by XponShop.
–If the product is malfunctional during use and under 12 months warranty, XponShop support team will contact you to troubleshoot the issue by professional diagnosis. The unsolvable problem will trigger the return procedure: repair, replace and reship to you or refund if repair or replacement is inapplicable.
NOTE:
· Please be aware that the product must be returned to the specified address as defined by shipping incoterms against the sales invoice/contract.
· For further information about how to return products, please contact our XponShop team at sales@xponshop.com, we will advise you on how to proceed.

Customer Reviews

Based on 1 review
100%
(1)
0%
(0)
0%
(0)
0%
(0)
0%
(0)
K
Katrina
Working great!

This switch S5720-28X-SI-DC has been working great so far.