Huawei CloudEngine S5735-S24T4X-I switch with 24-port 1000Base-T, 4-port 10GE SFP+, 2 power slots, PN# 98010960
Forwarding performance: 95.2 Mpps
Switching capacity:128 Gbps/336 Gbps
Applicable power module:
PAC60S12-AR (60 W AC&240 V DC Power Module)
PDC180S12-CR (180 W DC Power Module)
Huawei CloudEngine S5735-S is a series of standard gigabit access switches that provide 24–48 flexible all-GE downlink ports and four fixed 10 GE uplink ports.
S5735-S switches are designed for scenarios such as enterprise campus network access and aggregation, as well as data center access. Built on next-generation, high-performance hardware and with the Huawei Versatile Routing Platform (VRP), CloudEngine S5735-S switches boast advanced features, such as enhanced Layer 3 functionality, simplified O&M, flexible Ethernet networking, and mature IPv6 capabilities.
| Specification | ||
| Physical specifications | Dimensions (H x W x D) | 43.6 mm x 442 mm x 420 mm |
| Chassis height | 1 U | |
| Chassis weight (including packaging) | 7.21 kg | |
| Fixed port | GE port | 24 |
| 10GE port | 4 | |
| Management port | ETH management port | Supported |
| Console port (RJ45) | Supported | |
| USB port | USB 2.0 | |
| CPU | Frequency | 1000 MHz |
| Core | 4 | |
| Storage | Memory (RAM) | 1 GB |
| Flash memory | Hardware: 512MB, of which 306MB is available for users | |
| Power supply system | Power supply type | 60 W AC |
| Power supply redundancy | 1+1 NOTE: the backup power supply is optional. | |
| Rated voltage range | AC input: 100 V AC to 240 V AC, 50/60 Hz
High-Voltage DC input: 240 V DC |
|
| Maximum voltage range | AC input: 90 V AC to 264 V AC, 47 Hz to 63 Hz
High-Voltage DC input: 190 V DC to 290 V DC |
|
| Maximum input current | 60 W AC: 2 A | |
| Maximum power consumption (100% throughput, full speed of fans) | 55.2 W | |
| Typical power consumption (30% of traffic load)
Tested according to ATIS standard EEE enabled |
36.8 W | |
| Minimum power consumption | 23.7 W | |
| Environment parameters | Short-term operating temperature | 0-1800m altitude: -40°C to +70°C
1800-5000m altitude: The operating temperature reduces by 1ºC every time the altitude increases by 220m. |
| Long-term operating temperature | 0-1800m altitude: -40°C to +65°C
1800-5000m altitude: The operating temperature reduces by 1ºC every time the altitude increases by 220m. |
|
| Reliability | MTBF (year)2 | 62.88 |
| MTTR (hour) | 2 | |
| Availability | > 0.99999 | |