Overview
  • Product Specifications
  • PON Service Board
  • Physical Specifications
Popular Products Reviews
ZTE ZXDU48 B600 60A AC/DC Power
Bulk Inquiry
ZTE ZXDU48 B600 60A AC/DC Power
5 Stars
  • EU/US/UK Input AC Power Cable Included
  • BATT Backup
  • Installed in OLT 19 inch Rack
Category: B600 series, Site Power, 50A-100A, ZTE, ZTE Site Power, 20 ISPs have ordered this in the past 4 weeks.
Availability: In Stock
Afghanistan
Albania
Algeria
American Samoa
Andorra
Angola
Anguilla
Antarctica
Antigua And Barbuda
Argentina
Armenia
Aruba
Australia
Austria
Azerbaijan
Bahamas The
Bahrain
Bangladesh
Barbados
Belarus
Belgium
Belize
Benin
Bermuda
Bhutan
Bolivia
Bosnia and Herzegovina
Botswana
Bouvet Island
Brazil
British Indian Ocean Territory
Brunei
Bulgaria
Burkina Faso
Burundi
Cambodia
Cameroon
Canada
Cape Verde
Cayman Islands
Central African Republic
Chad
Chile
China
Christmas Island
Cocos (Keeling) Islands
Colombia
Comoros
Republic Of The Congo
Democratic Republic Of The Congo
Cook Islands
Costa Rica
Cote D'Ivoire (Ivory Coast)
Croatia (Hrvatska)
Cuba
Cyprus
Czech Republic
Denmark
Djibouti
Dominica
Dominican Republic
East Timor
Ecuador
Egypt
El Salvador
Equatorial Guinea
Eritrea
Estonia
Ethiopia
External Territories of Australia
Falkland Islands
Faroe Islands
Fiji Islands
Finland
France
French Guiana
French Polynesia
French Southern Territories
Gabon
Gambia The
Georgia
Germany
Ghana
Gibraltar
Greece
Greenland
Grenada
Guadeloupe
Guam
Guatemala
Guernsey and Alderney
Guinea
Guinea-Bissau
Guyana
Haiti
Heard and McDonald Islands
Honduras
Hong Kong S.A.R.
Hungary
Iceland
India
Indonesia
Iran
Iraq
Ireland
Israel
Italy
Jamaica
Japan
Jersey
Jordan
Kazakhstan
Kenya
Kiribati
Korea North
Korea South
Kuwait
Kyrgyzstan
Laos
Latvia
Lebanon
Lesotho
Liberia
Libya
Liechtenstein
Lithuania
Luxembourg
Macau S.A.R.
Macedonia
Madagascar
Malawi
Malaysia
Maldives
Mali
Malta
Man (Isle of)
Marshall Islands
Martinique
Mauritania
Mauritius
Mayotte
Mexico
Micronesia
Moldova
Monaco
Mongolia
Montserrat
Morocco
Mozambique
Myanmar
Namibia
Nauru
Nepal
Netherlands Antilles
Netherlands The
New Caledonia
New Zealand
Nicaragua
Niger
Nigeria
Niue
Norfolk Island
Northern Mariana Islands
Norway
Oman
Pakistan
Palau
Palestinian Territory Occupied
Panama
Papua new Guinea
Paraguay
Peru
Philippines
Pitcairn Island
Poland
Portugal
Puerto Rico
Qatar
Reunion
Romania
Russia
Rwanda
Saint Helena
Saint Kitts And Nevis
Saint Lucia
Saint Pierre and Miquelon
Saint Vincent And The Grenadines
Samoa
San Marino
Sao Tome and Principe
Saudi Arabia
Senegal
Serbia
Seychelles
Sierra Leone
Singapore
Slovakia
Slovenia
Smaller Territories of the UK
Solomon Islands
Somalia
South Africa
South Georgia
South Sudan
Spain
Sri Lanka
Sudan
Suriname
Svalbard And Jan Mayen Islands
Swaziland
Sweden
Switzerland
Syria
Taiwan
Tajikistan
Tanzania
Thailand
Togo
Tokelau
Tonga
Trinidad And Tobago
Tunisia
Turkey
Turkmenistan
Turks And Caicos Islands
Tuvalu
Uganda
Ukraine
United Arab Emirates
United Kingdom
United States
United States Minor Outlying Islands
Uruguay
Uzbekistan
Vanuatu
Vatican City State (Holy See)
Venezuela
Vietnam
Virgin Islands (British)
Virgin Islands (US)
Wallis And Futuna Islands
Western Sahara
Yemen
Yugoslavia
Zambia
Zimbabwe

It supports 220V single-live wire voltage input and 110V dual-live wire input.

It operates in the phase-to-neutral voltage range from 85V to 295V.

The rated DC output voltage is -53.5V and continuously adjustable from -42V to -58V

Provides input/output dry contacts and RS232 ports.

 

Specification
Item  Description

Operating temperature

-33℃ to +55℃

Sheds the load when they system operates in a temperature higher than 55℃

Powers off automatically when the system temperature is higher than 75℃

Storage temperature

-45℃ to +70℃

Relative humidity

5% to 95% (non-condensing). It is recommended that the relative humidity is in the range of 40% to 60%

Altitude

0m to 2000m: Outputs in full power

2000m to 3000m: Derated by 1% for every 100m increase of altitude

Space requirement The system must be installed in a 19-inch cabinet or rack.

The system must be horizontally installed. The cabinet must be definitely vertical. No bump is allowed.

There should be no liquid or conductive objects within, or dropping into the cabinet.

The system must not be installed near any water, corrosive gas, or explosive materials.

There should be no conductive dust or electromagnetic interference in the vicinity.

 System capacity 3200W/66A. Two ZXD1500 rectifiers are required for full configuration
 System efficiency Peak efficiency: 95%
 

Power limitation based on the input voltage

    

AC input ≤85 V± 5 V

The output power of the rectifier is 0%.
 

AC input (85 V±5 V) to 110 V

 

The power drops linearly. The output power of the rectifier ranges from 40% to 60% of the overall power.

 

AC input 110 V to 176 V

 

The power drops linearly. The output power of the rectifier ranges from 60% to 100% of the overall power.

 

AC input 176 V to (305 V±5 V)

 

The output power of the rectifier is 100%.

 

AC input >305 V±5 V

 

The output power of the rectifier is 0%.

 

Power limitation based on the temperature

  
Ambient temperature: -33℃ to +55℃ The output power of the rectifier is 100%
Ambient temperature: +55℃ to +75℃  The output power decreases linearly as the temperature rises. When the environmental temperature reaches 70°C, the output power is no lower than 62.6% of the maximum power.
Ambient temperature: >+75°C  The output power of the rectifier is 0% (power-off protection)
Over all noise (sound pressure) ≤68 dB(A)
Network architecture for monitoring RS232 ports connected in series
 Mean time between failures MTBF≥3.2x 10⁵ h
Design life  10 years to 15 years
Input AC features AC input mode  Three-wire single-phase system (LN/PE). Compatible with dual-live wires (L1/L2/PE)
Input AC voltage Rated phase-to-neutral voltage: 200 V to 240 V

Range of phase-to-neutral voltage: 85 V to 295 V

Input frequency Rated frequency: 50 Hz/60 Hz

Frequency range: 45 Hz to 66Hz

Input PF The PF is no lower than 0.996 at the rated load.
Total harmonic distortion  THD≤5% when the system operates at a power ranging from 30% to 100% of the rated power.
AC lightning protection  A lightning protection module is embedded in the rectifier.
 AC power distribution   Number of AC inputs  1
AC input circuit breaker  3xrimping terminals
Stanby AC output  -
Protection feature AC overvoltage protection  The overvoltage protection takes effect when the single-phase input voltage is higher than the AC overvoltage protection threshold.
AC undervoltage protection  The undervoltage protection takes effect when the single-phase input voltage is lower than the AC under voltage protection threshold.
Output DC properties Rated DC output voltage  -53.5 V DC
Range of the DC output voltage  Continuously adjustable from -41 V to -58 V (adjust by the CSU)
Voltage drop in the cabinet  ≤500 mV

Regulated voltage precision

≤0.6%

Psophometrically weighted noise voltage

≤2 mV

DC lightning

Maximum current of the lightning arrester: Imax = 3 kA (8/20 μs)

DC power distribution

Battery inputs

One input. 1 x 30 A, configured with a 40 A fusible link

Protection feature

Power-off protection mode

Battery Low Voltage Disconnect (BLVD)

DC load outputs

Two outputs. 2 x 20 A, configured with a 40 A fusible link

DC overvoltage protection

The overvoltage protection takes effect when the output voltage is higher than the DC overvoltage protection threshold.

DC undervoltage protection

The undervoltage protection takes effect when the output voltage is lower than the DC overvoltage protection threshold.

Battery undervoltage protection

The power-off protection takes effect when the battery voltage is lower than the power -off voltage protection threshold.

Dimensions

1U height / 19-inch width

43.6 mm x 482.6 mm x 260 mm (Height x Width x Depth)

Overall weight (including the rectifiers)

Around 8 kg

Installation mode

Embedded in a 19-inch cabinet

Customer Reviews Write a review Cancel review

Click to upload

C
C******r 17/11/2023
Good choice! This recitifer is suitable to our need with battery port and cheaper price.
S
S****n 12/01/2024
Can replace the ETP4860 I used to buy ETP4860-B1A1, XPONSHOP recommended it to me when they got the cheaper B600, which helped me save a lot. Thanks!
Sale Huawei H906CGHF 16-port XG-PON and GPON combo Board for MA5800 series OLT Bulk Inquiry
Sale Huawei H801MCUD1 Main Control Board for MA5608T OLT Bulk Inquiry
Sale Huawei H801GICF 2-port GE Uplink Board for MA5680T/MA5683T OLT Bulk Inquiry
Sale ZTE GFGL 16-port GPON Board for ZTE ZXA10 C600 series OLT Bulk Inquiry