iMaster OmniSight-T License Troubleshooting— OSN1800 Lack of License 22 Oct, 2025. Posted by:XPONSHOP
Issue Description  
iMaster OmniSight-T License Troubleshooting— OSN1800 Lack of License
iMaster OmniSight-T License Troubleshooting— OSN1800 Lack of License
 Alarm Information

the service capacity exceeds the license limit. Error Code: 43888

Handling Process

1. Please check the U2000 License resource control capacity for 1800 SDH Function.

2. Please reload the license again.

iMaster OmniSight-T License Troubleshooting— OSN1800 Lack of License

Root Cause

Due to the lack of iMaster OmniSight-T License, some functions or features of 1800V (OSN 9800 or OSN 9600) are controled while iManager U2000 license are only for the Basic function.

iMaster OmniSight-T License Troubleshooting— OSN1800 Lack of License

Solution

Please apply and add the Omnisight license in U2000 Client and load the capacity in Rack configuration.