Huawei NE40E-X3 Subrack including Dual AC/DC Power Options
Huawei NE40E series are high-end Ethernet network products that are developed based on the VRP routing platform and focus on the access, aggregation, and transmission of metro Ethernet services.
Slot Layout of the NE40E-X3
Specifications of the CR52-BKPE-4U-DC_NE40E-X3 Integrated DC Chassis(4 U)
Item | Specification |
Cabinet installation standards | Can be installed in a standard 19" 800 mm-deep cabinet. A Huawei 2.2 m-high N68E cabinet is used by default. |
Dimensions without packaging (H x W x D) [mm(in.)] | 175 mm x 442 mm x 650 mm (6.89 in. x 17.40 in. x 25.59 in.) |
Chassis height [U] | 4 U |
Weight without packaging [kg(lb)] | 15 kg (33.07 lb) |
Weight without packaging (full configuration) [kg(lb)] | 42 kg (92.59 lb) |
Typical power consumption (with configuration) [W] | 800 W (fully configured with LPUF-51s) |
920 W (fully configured with LPUF-120s) | |
1239 W (fully configured with LPUF-241s) | |
Typical heat dissipation (with configuration) [BTU/hour] | 2595.5 BTU/hour (fully configured with LPUF-51s) |
2984.9 BTU/hour (fully configured with LPUF-120s) | |
4019.8 BTU/hour (fully configured with LPUF-241s) | |
MTBF [year] | 27.44 year |
MTTR [hour] | 0.5 hour |
Availability | 0.99999792 |
Power supply mode | DC built-in |
Maximum number of power chassis inputs | (1 channel/PEM)*2 PEM=2 channels |
Rated input voltage [V] | –48 V/ –60 V |
Input voltage range [V] | –38.4 V to –72 V |
Maximum input current [A] | 42 A/single-module |
Maximum input cable size [mm²] | 25 mm² |
Front-end circuit breaker/fuse [A] | 50 A |
Noise at normal temperature (acoustic power) [dB(A)] | ETSI-compliance ( |
Number of slots | 5 |
Number of service board slots | 3 |
Switching capacity | 1.08 Tbit/s |
Redundant MPUs | 1:01 |
Redundant power supply | 1+1 |
Redundant fans | Support for proper fan operation in case of a single fan failure for a short period at 40°C (104°F) |
Long-term operating temperature [°C(°F)] | 0°C to 45°C (32°F to 113°F) |
Short-term operating temperature [°C(°F)] | -5°C to 55°C (23°F to 131°F) |
Restriction on the operating temperature variation rate [°C(°F)] | ≤ 0.5°C/min (32.9°F/min), non-condensing |
Storage temperature [°C(°F)] | -40°C to 70°C (-40°F to 158°F) |
Long-term operating relative humidity [RH] | 5% RH to 85% RH, non-condensing |
Short-term operating relative humidity [RH] | 5% RH to 95% RH, non-condensing |
Storage relative humidity [RH] | 5% RH to 95% RH, non-condensing |
Long-term operating altitude [m(ft.)] | ≤ 4000 m (13123.36 ft.) (From 1800 m to 4000 m [5905.51 ft. to 13123.36 ft.], the operating temperature of the device decreases by 1°C [1.8°F] for every 220 m [721.78 ft.] increase in altitude.) |
Specifications of the CR5B0BKP0370_NE40E-X3 Integrated AC Chassis (5 U)
Item | Specification |
Cabinet installation standards | Can be installed in a standard 19" 800 mm-deep cabinet. A Huawei 2.2 m-high N68E cabinet is used by default. |
Dimensions without packaging (H x W x D) [mm(in.)] | 220 mm x 442 mm x 650 mm (8.66 in. x 17.40 in. x 25.59 in.) |
Chassis height [U] | 5 U |
Weight without packaging [kg(lb)] | 25 kg (55.12 lb) |
Weight without packaging (full configuration) [kg(lb)] | 52 kg (114.64 lb) |
Typical power consumption (with configuration) [W] | 950 W (fully configured with LPUF-51s) |
1070 W (fully configured with LPUF-120s) | |
1386 W (fully configured with LPUF-241s) | |
Typical heat dissipation (with configuration) [BTU/hour] | 3082.2 BTU/hour (fully configured with LPUF-51s) |
3471.5 BTU/hour (fully configured with LPUF-120s) | |
4496.8 BTU/hour (fully configured with LPUF-241s) | |
MTBF [year] | 27.44 year |
MTTR [hour] | 0.5 hour |
Availability | 0.99999792 |
Power supply mode | AC built-in |
Maximum number of power chassis inputs | (1 channel/PEM)*2 PEM=2 channels |
Rated input voltage [V] | 200 V to 240 V |
Input voltage range [V] | 180 V to 264 V |
Maximum input current [A] | 12A/single-module |
Maximum input cable size [mm²] | Standard C19 cable |
Front-end circuit breaker/fuse [A] | 16 A |
Noise at normal temperature (acoustic power) [dB(A)] | ETSI-compliance ( |
Number of slots | 5 |
Number of service board slots | 3 |
Switching capacity | 1.08 Tbit/s |
Redundant MPUs | 1:01 |
Redundant power supply | 1+1 |
Redundant fans | Support for proper fan operation in case of a single fan failure for a short period at 40°C (104°F) |
Long-term operating temperature [°C(°F)] | 0°C to 45°C (32°F to 113°F) |
Short-term operating temperature [°C(°F)] | -5°C to 55°C (23°F to 131°F) |
Restriction on the operating temperature variation rate [°C(°F)] | ≤ 0.5°C/min (32.9°F/min), non-condensing |
Storage temperature [°C(°F)] | -40°C to 70°C (-40°F to 158°F) |
Long-term operating relative humidity [RH] | 5% RH to 85% RH, non-condensing |
Short-term operating relative humidity [RH] | 5% RH to 95% RH, non-condensing |
Storage relative humidity [RH] | 5% RH to 95% RH, non-condensing |
Long-term operating altitude [m(ft.)] | ≤ 4000 m (13123.36 ft.) (From 1800 m to 4000 m [5905.51 ft. to 13123.36 ft.], the operating temperature of the device decreases by 1°C [1.8°F] for every 220 m [721.78 ft.] increase in altitude.) |
Storage altitude [m(ft.)] |