Huawei MA5608T OLT 19inch Chassis
- Brand New Condition
- Latest 3rd-Party ONTs Compatible Firmware Loaded
- Latest Manufacture Year
- 2 Pairs 6mm² Power Cable Included
- Blank Panel Included
- Category:GPON OLT,Huawei,MA5600T OLT
Huawei MA5608T belonging to Huawei SmartAX MA5600T series OLT products includes the MA5608T, MA5683T, and MA5680T OLT in Huawei FTTH solution.
Huawei MA5608T OLT H801MABR subrack
Serves as the CO OLT and supports multiple network construction modes and diversified access media to provide access for home users, mobile users, and enterprise users
User access: provides access for home users, mobile users, and enterprise users
Network construction mode: supports FTTH, FTTB, FTTC, FTTW, FTTO, and FTTD networks
Access media: supports copper, fiber, cable, and Wi-Fi access
Supports aggregation management and plug-and-play for remote site, High-efficiency deployment, Fast integration and Easy OAM
Provides access for various traditional services, enabling a PSTN network seamlessly evolve to an IP network
Provides 3 protection mechanisms on the network side, access side, and device to ensure that services are not interrupted
Can be smoothly upgraded from GPON to 10G GPON by adding the WDM1r component
Specification | |
Backplane bus switching capacity | 720 Gbit/s |
System L2 packet forwarding rate | MCUD/MCUD1: 190Mpps(Active/Standby mode), 380Mpps(Load-sharing mode) |
Control board switching capacity | MCUD/MCUD1: 128Gbit/s(Active/Standby mode),256Gbit/s(Load-sharing mode) |
Switching/Forwarding delay | Short forwarding delay: The 100 Mbit/s Ethernet port sends the 64-byte Ethernet packets at a delay shorter than 20 μs. |
BER in full load | BER of port when transmitting data in full load < 10 e-7 |
Configuration | |
Maintenance port | Number of 10 Mbit/s/100 Mbit/s maintenance Ethernet ports: 1 |
Number of serial ports for local/remote maintenance: 1 | |
Monitoring port | Number of environment monitoring serial ports: 1 |
Maximum number of ADSL2+ ports in a subrack | 128 |
Maximum number of VDSL2 ports in a subrack | 128 |
Maximum number of EFM SHDSL ports in a subrack | 64 NOTE: The MA5608T only supports the EFM SHDSL ports. |
Maximum number of TDM SHDSL ports in a subrack | 32 |
Maximum number of POTS ports in a subrack | 128 |
Maximum number of ISDN BRA ports in a subrack | 64 |
Maximum number of ISDN PRA ports in a subrack | 64 |
Maximum number of GPON ports in a subrack | 32 |
Maximum number of 10G GPON ports in a subrack | 16 |
Maximum number of P2P FE ports in a subrack | 96 |
Maximum number of P2P GE ports in a subrack | 96 |
Management ports | |
Outband management Ethernet port (RJ-45) | MCUD/MCUD1 |
Local serial port (Console) | MCUD/MCUD1 |
Upstream ports | |
GE optical port | MCUD1: 2 Ports Board |
MCUD:4 Ports Board | |
ETHB/SPUF: 8 Ports Board | |
10GE optical port | MCUD1: 2 Ports Board |
SPUF: 8 Ports Board | |
E1 port | TOPA: 16 Ports Board |
STM-1 upstream optical port | TOPA: 2 Ports Board |
Service ports | |
GPON port | GPBD/GPBH: 8 Ports Board |
GPFD: 16 Ports Board | |
10G GPON port | XGBC: 4 Ports Board |
XGBD: 8 Ports Board | |
P2P GE optical port | OPGD/OPGE: Single-fiber bi-directional: 48 Ports Board, Two-fiber bi-directional: 24 Ports Board |
P2P FE optical port | OPGD/OPGE: Single-fiber bi-directional: 48 Ports Board, Two-fiber bi-directional: 24 Ports Board |
Ethernet optical port | ETHB: 8 Ports Board |
E1 port | H802EDTB: 16 Ports Board |
ADSL2+ | ADPD/ADPM/ADPE : 64 Ports Board |
VDSL2 | VDRD : 24 Ports Board |
VDMF/VCMM : 48 Ports Board | |
VDPM/VDQM/VDPE/VDPD/VCPE : 64 Ports Board | |
EFM SHDSL | SHLM : 16 Ports Board |
SHGM : 32 Ports Board | |
TDM SHDSL | H802EDTB: 16 Ports Board |
POTS | ASPB : 64 Ports Board |
ADSL2+&POTS | CAME : 48 Ports Board |
VDSL2&POTS | CVME : 48 Ports Board |
CCPE : 64 Ports Board | |
ISDN BRA | DSRD/DSRE :32 Ports Board |
Power parameters | |
Power supply mode | DC MPWC or AC MPWD |
Rated voltage | DC power supply: -48 V / -60 V AC power supply: 110 V / 220 V |
Working voltage range | DC power supply: -38.4 V to -72 V AC power supply: 100 V to 240 V |
Maximum input current | DC power supply: 10 A AC power supply: 6 A |
Working environment temperature | -40°C to +65°C |
Working environment humidity | 5% RH to 95% RH |
Atmosphere pressure | 61 kPa to 106 kPa |
Altitude | < 4000 m |
Device Specifications | |
Dimensions (W x D x H, excluding mounting brackets) | 442mm×244.5mm×88.1mm |
Dimensions (W x D x H, including mounting brackets) | 535mm×244.5mm×88.1mm, for ETSI cabinet NOTE:ETSI standard dimension is to add the ETSI mounting bracket on the IEC mounting bracket. |
482.6mm×244.5mm×88.1mm, for IEC cabinet | |
Weight (empty chassis) | 3.55KG |
SmartAX MA5600T Series OLT
Item | MA5600T(ETSI)/MA5680T | MA5600T(IEC)/MA5680T | MA5603T/MA5683T | MA5608T |
Supported cabinet | Indoor cabinet: N63E-22, N66E-18 | Indoor cabinet: N66E-22 | Indoor cabinet: N66E-18 | Indoor cabinet: N63E-22 |
Outdoor cabinet: F01D500, F01D2000 | Outdoor cabinet: none | Outdoor cabinet: F01D500, F01S300 | Outdoor cabinet: F01S200 | |
Board configuration | 2 slots for control boards | 2 slots for control boards | 2 slots for control boards | 2 slots for control boards |
16 slots for service boards | 14 slots for service boards | 6 slots for service boards | 2 slots for service boards | |
1 slot for the universal interface board | 1 slot for the universal interface board | 1 slot for the universal interface board | 2 slots for the power interface board. | |
2 slots for upstream interface boards | 2 slots for upstream interface boards | 2 slots for upstream interface boards | ||
2 slots for power interface boards. | 2 slots for power interface boards. | 2 slots for power interface boards. | ||
Switching capacity of the backplane bus | 3.2 Tbit/s | 1.5 Tbit/s (H801MABO) | 720 Gbit/s | |
2 Tbit/s (H802MABO) | ||||
Supported control board and its switching capacity | SCUN: 480 Gbit/s in active/standby mode or 960 Gbit/s in load-sharing mode | MCUD/MCUD1: 128 Gbit/s in active/standby mode or 256 Gbit/s in load-sharing mode | ||
SCUH: 960 Gbit/s in active/standby mode or 1920 Gbit/s in load-sharing mode | ||||
SCUB: 48 Gbit/s | ||||
SCUF: 128 Gbit/s | ||||
System Layer 2 packet forwarding rate | SCUN: 726 Mpps in active/standby mode or 1452 Mpps in load-sharing mode | MCUD/MCUD1: 190 Mpps in active/standby mode or 380 Mpps in load-sharing mode | ||
SCUH: 1428 Mpps in active/standby mode or 2856 Mpps in load-sharing mode | ||||
SCUB: 72 Mpps | ||||
SCUF: 190 Mpps | ||||
Switching/Forwarding delay | Short forwarding delay: The 100 Mbit/s Ethernet port sends the 64-byte Ethernet packets at a delay shorter than 20 渭s. | |||
BER in full load | BER of a port when the port transmits data in full load < 10 e-7 | |||
System reliability specifications | System: redundant configuration. | |||
System availability for the typical configuration: > 99.999% | ||||
Mean time between failures (MTBF): about 45 years. | ||||
NOTE: | ||||
Due to different network environments and different boards used by devices, the preceding MTBF (45 years) of theMA5600T/MA5603T/MA5608Tis only for reference. The average repair time for field replaceable units (FRUs) is about 2 hours. The preceding values are only for reference. For details, contact the related Huawei engineers. | ||||
Maximum number of ADSL2+ ports in a subrack | 1024 | 896 | 384 | 128 |
Maximum number of VDSL2 ports in a subrack | 1024 | 896 | 384 | 128 |
Maximum number of EFM SHDSL ports in a subrack | 512 | 448 | 192 | 64 |
Maximum number of TDM SHDSL ports in a subrack | 256 | 224 | 96 | 32 |
Maximum number of POTS ports in a subrack | 1024 | 896 | 384 | 128 |
Maximum number of ISDN BRA ports in a subrack | 512 | 448 | 192 | 64 |
Maximum number of ISDN PRA ports in a subrack | 64 | 56 | 64 | 64 |
Maximum number of GPON ports in a subrack | 256 | 224 | 96 | 32 |
Maximum number of 10G GPON ports in a subrack | 128 | 112 | 48 | 16 |
Maximum number of P2P FE ports in a subrack | 768 | 672 | 288 | 96 |
Maximum number of P2P GE ports in a subrack | 768 | 672 | 288 | 96 |
Maximum number of upstream ports (GE ports in the GIU slot) in a subrack | 8 | 8 | 8 | - |
Maximum number of upstream ports (10GE ports in the GIU slot) in a subrack | 4 | 4 | 4 | - |
Maximum number of upstream ports (PON ports in the GIU slot) in a subrack | 2 (in the active/standby mode) | 2 (in the active/standby mode) | 2 | - |
Maximum number of upstream ports (ports on the control board) in a subrack | SCUN/SCUK: 8 x GE (in the load-sharing mode) | MCUD: 8 x GE (in the load-sharing mode) | ||
SCUH: 8 x 10GE (in the load-sharing mode) | MCUD1: 4 x GE + 2 x 10GE (in the load-sharing mode) | |||
SCUB/SCUF: 4 x GE (in the active/standby mode) | ||||
Maximum number of extended subracks connected to a master subrack | 32 | 32 | 32 | - |
Maximum number of ONUs supported by each subrack |
For Layer 2 applications, the maximum number of ONUs supported by each subrack is determined based on the number of MAC addresses and service flows supported by the control board, as well as the number of MAC addresses and service flows planned for the ONUs. For Layer 3 applications, the maximum number of ONUs supported by each subrack is determined based on the number of routes and ARP entries supported by the control board. |
Comparison of MA5600T Series OLT GPON service board
Specification | H801GPBC | H802GPBD | H805GPBD | H802GPFD/H805GPFD | H806GPBH/H807GPBH | H801GPMD |
Port quantity | 4 | 8 | 8 | 16 | 8 | 8 |
MAX Split ratio (Class B+) | 1:64 | 1:64 | 1:64 | 1:64 | 1:64 | 1:64 |
MAX Split ratio (Class C+/Class C++) | Not support | 1: 128 | 1: 128 | 1: 128 | 1: 128 | 1: 128 |
D-CMTS | No | No | No | No | No | Yes |
ONU-based shaping | No | No | Yes | Yes | Yes | Yes |
Optical performance monitor | Yes (querying Rx optical power is not supported) | Yes | Yes | Yes | Yes | Yes |
RSSI detection and controlled optical signal transmission of the optical module | No | Yes | Yes | Yes | Yes | Yes |
ONU-based rate limitation | × | √ | √ | √ | √ | √ |
CAR group | × | √ | √ | √ | √ | √ |
Temperature query and high temperature alarm | Yes | Yes | Yes | Yes | Yes | Yes |
Automatic power shutdown in case of a high temperature | No | Yes | Yes | Yes | Yes | Yes |
Maximum differential fibre distance (km) | 20 | 20 | 20 | 40 | 40 | 40 |
Maximum Number of Service Flows Supported by the Board | 8184 | 8184 | 8184 | 16368 | 8184 | 6144 |
Maximum Number of MAC address Supported by the Board | 32768 | 32768 | 32768 | 32768 | 32768 | 32768 |
Available DBA bandwidth (based on single port) (kbit/s) | 1238400 | 1238784 | 1238784 | 1238784 | 1238784 | 1238784 |
Number of T-CONT supported by each GPON port | 256 | 1024 | 1024 | 1024 | 1024 | 1024 |
Board supporting downstream FEC | Yes | Yes | Yes | Yes | Yes | Yes |
Board supporting upstream FEC | No | Yes | Yes | Yes | Yes | Yes |
Rogue ONT detection | No | Yes | Yes | Yes | Yes | Yes |
Number of ONUs supported by a GPON port | 64 | 128 | 128 | 128 | 128 | 128 |
Number of GEM ports supported by each board | 8192 | 8192 | 8192 | 16384 | 8192 | 8192 |
Number of GEM ports supported by each GPON port | 3872 | 3872 | 3872 | 3872 | 3872 | 3872 |
Number of service ports supported by each GEM port | 8 | 8 | 8184 | 8184 | 8184 | 7168 |
HQoS (four levels) | × | × | × | H802GPFD: × | H806GPBH: × | × |
H805GPFD: √ | H807GPBH: √ | |||||
9216-byte Jumbo frames | × | × | × | H802GPFD: × | H806GPBH: × | × |
H805GPFD: √ | H807GPBH: √ | |||||
Power budget supported by a GPON port | Class B+ (28.5 dB, mostly used) | Class B+ (28.5 dB, mostly used), | ||||
Class C+ (32 dB long reach transmission) | ||||||
Class C++: 35 dB | ||||||
Minimum bandwidth supported by a T-CONT | 512kbps | 1 Mbit/s (in the minimum delay mode) | ||||
128 kbit/s (in the maximum bandwidth usage mode) |
Huawei MA5608T belonging to Huawei SmartAX MA5600T series OLT products includes the MA5608T, MA5683T, and MA5680T OLT in Huawei FTTH solution.
Huawei MA5608T OLT H801MABR subrack
Serves as the CO OLT and supports multiple network construction modes and diversified access media to provide access for home users, mobile users, and enterprise users
User access: provides access for home users, mobile users, and enterprise users
Network construction mode: supports FTTH, FTTB, FTTC, FTTW, FTTO, and FTTD networks
Access media: supports copper, fiber, cable, and Wi-Fi access
Supports aggregation management and plug-and-play for remote site, High-efficiency deployment, Fast integration and Easy OAM
Provides access for various traditional services, enabling a PSTN network seamlessly evolve to an IP network
Provides 3 protection mechanisms on the network side, access side, and device to ensure that services are not interrupted
Can be smoothly upgraded from GPON to 10G GPON by adding the WDM1r component
Specification | |
Backplane bus switching capacity | 720 Gbit/s |
System L2 packet forwarding rate | MCUD/MCUD1: 190Mpps(Active/Standby mode), 380Mpps(Load-sharing mode) |
Control board switching capacity | MCUD/MCUD1: 128Gbit/s(Active/Standby mode),256Gbit/s(Load-sharing mode) |
Switching/Forwarding delay | Short forwarding delay: The 100 Mbit/s Ethernet port sends the 64-byte Ethernet packets at a delay shorter than 20 μs. |
BER in full load | BER of port when transmitting data in full load < 10 e-7 |
Configuration | |
Maintenance port | Number of 10 Mbit/s/100 Mbit/s maintenance Ethernet ports: 1 |
Number of serial ports for local/remote maintenance: 1 | |
Monitoring port | Number of environment monitoring serial ports: 1 |
Maximum number of ADSL2+ ports in a subrack | 128 |
Maximum number of VDSL2 ports in a subrack | 128 |
Maximum number of EFM SHDSL ports in a subrack | 64 NOTE: The MA5608T only supports the EFM SHDSL ports. |
Maximum number of TDM SHDSL ports in a subrack | 32 |
Maximum number of POTS ports in a subrack | 128 |
Maximum number of ISDN BRA ports in a subrack | 64 |
Maximum number of ISDN PRA ports in a subrack | 64 |
Maximum number of GPON ports in a subrack | 32 |
Maximum number of 10G GPON ports in a subrack | 16 |
Maximum number of P2P FE ports in a subrack | 96 |
Maximum number of P2P GE ports in a subrack | 96 |
Management ports | |
Outband management Ethernet port (RJ-45) | MCUD/MCUD1 |
Local serial port (Console) | MCUD/MCUD1 |
Upstream ports | |
GE optical port | MCUD1: 2 Ports Board |
MCUD:4 Ports Board | |
ETHB/SPUF: 8 Ports Board | |
10GE optical port | MCUD1: 2 Ports Board |
SPUF: 8 Ports Board | |
E1 port | TOPA: 16 Ports Board |
STM-1 upstream optical port | TOPA: 2 Ports Board |
Service ports | |
GPON port | GPBD/GPBH: 8 Ports Board |
GPFD: 16 Ports Board | |
10G GPON port | XGBC: 4 Ports Board |
XGBD: 8 Ports Board | |
P2P GE optical port | OPGD/OPGE: Single-fiber bi-directional: 48 Ports Board, Two-fiber bi-directional: 24 Ports Board |
P2P FE optical port | OPGD/OPGE: Single-fiber bi-directional: 48 Ports Board, Two-fiber bi-directional: 24 Ports Board |
Ethernet optical port | ETHB: 8 Ports Board |
E1 port | H802EDTB: 16 Ports Board |
ADSL2+ | ADPD/ADPM/ADPE : 64 Ports Board |
VDSL2 | VDRD : 24 Ports Board |
VDMF/VCMM : 48 Ports Board | |
VDPM/VDQM/VDPE/VDPD/VCPE : 64 Ports Board | |
EFM SHDSL | SHLM : 16 Ports Board |
SHGM : 32 Ports Board | |
TDM SHDSL | H802EDTB: 16 Ports Board |
POTS | ASPB : 64 Ports Board |
ADSL2+&POTS | CAME : 48 Ports Board |
VDSL2&POTS | CVME : 48 Ports Board |
CCPE : 64 Ports Board | |
ISDN BRA | DSRD/DSRE :32 Ports Board |
Power parameters | |
Power supply mode | DC MPWC or AC MPWD |
Rated voltage | DC power supply: -48 V / -60 V AC power supply: 110 V / 220 V |
Working voltage range | DC power supply: -38.4 V to -72 V AC power supply: 100 V to 240 V |
Maximum input current | DC power supply: 10 A AC power supply: 6 A |
Working environment temperature | -40°C to +65°C |
Working environment humidity | 5% RH to 95% RH |
Atmosphere pressure | 61 kPa to 106 kPa |
Altitude | < 4000 m |
Device Specifications | |
Dimensions (W x D x H, excluding mounting brackets) | 442mm×244.5mm×88.1mm |
Dimensions (W x D x H, including mounting brackets) | 535mm×244.5mm×88.1mm, for ETSI cabinet NOTE:ETSI standard dimension is to add the ETSI mounting bracket on the IEC mounting bracket. |
482.6mm×244.5mm×88.1mm, for IEC cabinet | |
Weight (empty chassis) | 3.55KG |
SmartAX MA5600T Series OLT
Item | MA5600T(ETSI)/MA5680T | MA5600T(IEC)/MA5680T | MA5603T/MA5683T | MA5608T |
Supported cabinet | Indoor cabinet: N63E-22, N66E-18 | Indoor cabinet: N66E-22 | Indoor cabinet: N66E-18 | Indoor cabinet: N63E-22 |
Outdoor cabinet: F01D500, F01D2000 | Outdoor cabinet: none | Outdoor cabinet: F01D500, F01S300 | Outdoor cabinet: F01S200 | |
Board configuration | 2 slots for control boards | 2 slots for control boards | 2 slots for control boards | 2 slots for control boards |
16 slots for service boards | 14 slots for service boards | 6 slots for service boards | 2 slots for service boards | |
1 slot for the universal interface board | 1 slot for the universal interface board | 1 slot for the universal interface board | 2 slots for the power interface board. | |
2 slots for upstream interface boards | 2 slots for upstream interface boards | 2 slots for upstream interface boards | ||
2 slots for power interface boards. | 2 slots for power interface boards. | 2 slots for power interface boards. | ||
Switching capacity of the backplane bus | 3.2 Tbit/s | 1.5 Tbit/s (H801MABO) | 720 Gbit/s | |
2 Tbit/s (H802MABO) | ||||
Supported control board and its switching capacity | SCUN: 480 Gbit/s in active/standby mode or 960 Gbit/s in load-sharing mode | MCUD/MCUD1: 128 Gbit/s in active/standby mode or 256 Gbit/s in load-sharing mode | ||
SCUH: 960 Gbit/s in active/standby mode or 1920 Gbit/s in load-sharing mode | ||||
SCUB: 48 Gbit/s | ||||
SCUF: 128 Gbit/s | ||||
System Layer 2 packet forwarding rate | SCUN: 726 Mpps in active/standby mode or 1452 Mpps in load-sharing mode | MCUD/MCUD1: 190 Mpps in active/standby mode or 380 Mpps in load-sharing mode | ||
SCUH: 1428 Mpps in active/standby mode or 2856 Mpps in load-sharing mode | ||||
SCUB: 72 Mpps | ||||
SCUF: 190 Mpps | ||||
Switching/Forwarding delay | Short forwarding delay: The 100 Mbit/s Ethernet port sends the 64-byte Ethernet packets at a delay shorter than 20 渭s. | |||
BER in full load | BER of a port when the port transmits data in full load < 10 e-7 | |||
System reliability specifications | System: redundant configuration. | |||
System availability for the typical configuration: > 99.999% | ||||
Mean time between failures (MTBF): about 45 years. | ||||
NOTE: | ||||
Due to different network environments and different boards used by devices, the preceding MTBF (45 years) of theMA5600T/MA5603T/MA5608Tis only for reference. The average repair time for field replaceable units (FRUs) is about 2 hours. The preceding values are only for reference. For details, contact the related Huawei engineers. | ||||
Maximum number of ADSL2+ ports in a subrack | 1024 | 896 | 384 | 128 |
Maximum number of VDSL2 ports in a subrack | 1024 | 896 | 384 | 128 |
Maximum number of EFM SHDSL ports in a subrack | 512 | 448 | 192 | 64 |
Maximum number of TDM SHDSL ports in a subrack | 256 | 224 | 96 | 32 |
Maximum number of POTS ports in a subrack | 1024 | 896 | 384 | 128 |
Maximum number of ISDN BRA ports in a subrack | 512 | 448 | 192 | 64 |
Maximum number of ISDN PRA ports in a subrack | 64 | 56 | 64 | 64 |
Maximum number of GPON ports in a subrack | 256 | 224 | 96 | 32 |
Maximum number of 10G GPON ports in a subrack | 128 | 112 | 48 | 16 |
Maximum number of P2P FE ports in a subrack | 768 | 672 | 288 | 96 |
Maximum number of P2P GE ports in a subrack | 768 | 672 | 288 | 96 |
Maximum number of upstream ports (GE ports in the GIU slot) in a subrack | 8 | 8 | 8 | - |
Maximum number of upstream ports (10GE ports in the GIU slot) in a subrack | 4 | 4 | 4 | - |
Maximum number of upstream ports (PON ports in the GIU slot) in a subrack | 2 (in the active/standby mode) | 2 (in the active/standby mode) | 2 | - |
Maximum number of upstream ports (ports on the control board) in a subrack | SCUN/SCUK: 8 x GE (in the load-sharing mode) | MCUD: 8 x GE (in the load-sharing mode) | ||
SCUH: 8 x 10GE (in the load-sharing mode) | MCUD1: 4 x GE + 2 x 10GE (in the load-sharing mode) | |||
SCUB/SCUF: 4 x GE (in the active/standby mode) | ||||
Maximum number of extended subracks connected to a master subrack | 32 | 32 | 32 | - |
Maximum number of ONUs supported by each subrack |
For Layer 2 applications, the maximum number of ONUs supported by each subrack is determined based on the number of MAC addresses and service flows supported by the control board, as well as the number of MAC addresses and service flows planned for the ONUs. For Layer 3 applications, the maximum number of ONUs supported by each subrack is determined based on the number of routes and ARP entries supported by the control board. |
Comparison of MA5600T Series OLT GPON service board
Specification | H801GPBC | H802GPBD | H805GPBD | H802GPFD/H805GPFD | H806GPBH/H807GPBH | H801GPMD |
Port quantity | 4 | 8 | 8 | 16 | 8 | 8 |
MAX Split ratio (Class B+) | 1:64 | 1:64 | 1:64 | 1:64 | 1:64 | 1:64 |
MAX Split ratio (Class C+/Class C++) | Not support | 1: 128 | 1: 128 | 1: 128 | 1: 128 | 1: 128 |
D-CMTS | No | No | No | No | No | Yes |
ONU-based shaping | No | No | Yes | Yes | Yes | Yes |
Optical performance monitor | Yes (querying Rx optical power is not supported) | Yes | Yes | Yes | Yes | Yes |
RSSI detection and controlled optical signal transmission of the optical module | No | Yes | Yes | Yes | Yes | Yes |
ONU-based rate limitation | × | √ | √ | √ | √ | √ |
CAR group | × | √ | √ | √ | √ | √ |
Temperature query and high temperature alarm | Yes | Yes | Yes | Yes | Yes | Yes |
Automatic power shutdown in case of a high temperature | No | Yes | Yes | Yes | Yes | Yes |
Maximum differential fibre distance (km) | 20 | 20 | 20 | 40 | 40 | 40 |
Maximum Number of Service Flows Supported by the Board | 8184 | 8184 | 8184 | 16368 | 8184 | 6144 |
Maximum Number of MAC address Supported by the Board | 32768 | 32768 | 32768 | 32768 | 32768 | 32768 |
Available DBA bandwidth (based on single port) (kbit/s) | 1238400 | 1238784 | 1238784 | 1238784 | 1238784 | 1238784 |
Number of T-CONT supported by each GPON port | 256 | 1024 | 1024 | 1024 | 1024 | 1024 |
Board supporting downstream FEC | Yes | Yes | Yes | Yes | Yes | Yes |
Board supporting upstream FEC | No | Yes | Yes | Yes | Yes | Yes |
Rogue ONT detection | No | Yes | Yes | Yes | Yes | Yes |
Number of ONUs supported by a GPON port | 64 | 128 | 128 | 128 | 128 | 128 |
Number of GEM ports supported by each board | 8192 | 8192 | 8192 | 16384 | 8192 | 8192 |
Number of GEM ports supported by each GPON port | 3872 | 3872 | 3872 | 3872 | 3872 | 3872 |
Number of service ports supported by each GEM port | 8 | 8 | 8184 | 8184 | 8184 | 7168 |
HQoS (four levels) | × | × | × | H802GPFD: × | H806GPBH: × | × |
H805GPFD: √ | H807GPBH: √ | |||||
9216-byte Jumbo frames | × | × | × | H802GPFD: × | H806GPBH: × | × |
H805GPFD: √ | H807GPBH: √ | |||||
Power budget supported by a GPON port | Class B+ (28.5 dB, mostly used) | Class B+ (28.5 dB, mostly used), | ||||
Class C+ (32 dB long reach transmission) | ||||||
Class C++: 35 dB | ||||||
Minimum bandwidth supported by a T-CONT | 512kbps | 1 Mbit/s (in the minimum delay mode) | ||||
128 kbit/s (in the maximum bandwidth usage mode) |
GLOBAL SHIPPING
XponShop offers you various options of shipping ways:
-EXW SHENZHEN
-Overseas Express which includes shipping by Carriers, by Air Cargo, and Sea Freight.
Cargo Weight/Volume | Suggested Shipping Ways | Comments |
≤ 45KGS | By Shipping Carriers (DHL, UPS, FedEx, etc.) | Door to door service, fast and convenient. |
>45KGS | By Air Cargo | Door to airport service, more cost-efficient. |
>1CBM | By Sea Freight | Large-volume goods, door to seaport service, longer shipping time but cheaper. |
XponShop makes the most commonly used trade terms available for your convenience: CNF, CPT, CIF, DDP, etc to ensure global fast and convenient delivery.
Once you confirm your order, you may contact XponShop team for calculating the freight charges and choose the optimal shipping way.
NOTE:
· Shipping may be subject to local taxes or duties; XponShop is not responsible for and has no control over these charges.
· No matter which shipping ways you chose, cargo insurance is highly recommended in case of unpredictable loss.
RETURN POLICY
We aim to deliver products for your appreciation and satisfaction. XponShop return or replacement policy applies only if the product is damaged or incorrectly delivered.
–If you receive a damaged product or it is different from the one requested, you can return or replace it within 7 days of receipt. In such a case, costs shall be borne by XponShop.
–If the product is malfunctional during use and under 12 months warranty, XponShop support team will contact you to troubleshoot the issue by professional diagnosis. The unsolvable problem will trigger the return procedure: repair, replace and reship to you or refund if repair or replacement is inapplicable.
NOTE:
· Please be aware that the product must be returned to the specified address as defined by shipping incoterms against the sales invoice/contract.
· For further information about how to return products, please contact our XponShop team at sales@xponshop.com, we will advise you on how to proceed.