Huawei MA5608T OLT 19inch Chassis

  • Brand New Condition
  • Latest 3rd-Party ONTs Compatible Firmware Loaded
  • Latest Manufacture Year
  • 2 Pairs 6mm² Power Cable Included
  • Blank Panel Included
Image
Available:In Stock
$0.00

Huawei MA5608T belonging to Huawei SmartAX MA5600T series OLT products includes the MA5608TMA5683T, and MA5680T OLT in Huawei FTTH solution.

Huawei MA5608T OLT H801MABR subrack

Serves as the CO OLT and supports multiple network construction modes and diversified access media to provide access for home users, mobile users, and enterprise users

User access: provides access for home users, mobile users, and enterprise users

Network construction mode: supports FTTH, FTTB, FTTC, FTTW, FTTO, and FTTD networks

Access media: supports copper, fiber, cable, and Wi-Fi access

Supports aggregation management and plug-and-play for remote site, High-efficiency deployment, Fast integration and Easy OAM

Provides access for various traditional services, enabling a PSTN network seamlessly evolve to an IP network

Provides 3 protection mechanisms on the network side, access side, and device to ensure that services are not interrupted

Can be smoothly upgraded from GPON to 10G GPON by adding the WDM1r component

Specification
Backplane bus switching capacity 720 Gbit/s
System L2 packet forwarding rate MCUD/MCUD1: 190Mpps(Active/Standby mode), 380Mpps(Load-sharing mode)
Control board switching capacity MCUD/MCUD1: 128Gbit/s(Active/Standby mode),256Gbit/s(Load-sharing mode)
Switching/Forwarding delay Short forwarding delay: The 100 Mbit/s Ethernet port sends the 64-byte Ethernet packets at a delay shorter than 20 μs.
BER in full load BER of port when transmitting data in full load < 10 e-7
Configuration
Maintenance port Number of 10 Mbit/s/100 Mbit/s maintenance Ethernet ports: 1
Number of serial ports for local/remote maintenance: 1
Monitoring port Number of environment monitoring serial ports: 1
Maximum number of ADSL2+ ports in a subrack 128
Maximum number of VDSL2 ports in a subrack 128
Maximum number of EFM SHDSL ports in a subrack 64  NOTE: The MA5608T only supports the EFM SHDSL ports.
Maximum number of TDM SHDSL ports in a subrack 32
Maximum number of POTS ports in a subrack 128
Maximum number of ISDN BRA ports in a subrack 64
Maximum number of ISDN PRA ports in a subrack 64
Maximum number of GPON ports in a subrack 32
Maximum number of 10G GPON ports in a subrack 16
Maximum number of P2P FE ports in a subrack 96
Maximum number of P2P GE ports in a subrack 96
Management ports
Outband management Ethernet port (RJ-45) MCUD/MCUD1
Local serial port (Console) MCUD/MCUD1
Upstream ports
GE optical port MCUD1: 2 Ports Board
MCUD:4 Ports Board
ETHB/SPUF: 8 Ports Board
10GE optical port MCUD1: 2 Ports Board
SPUF: 8 Ports Board
E1 port TOPA: 16 Ports Board
STM-1 upstream optical port TOPA: 2 Ports Board
Service ports
GPON port GPBD/GPBH: 8 Ports Board
GPFD: 16 Ports Board
10G GPON port XGBC: 4 Ports Board
XGBD: 8 Ports Board
P2P GE optical port OPGD/OPGE: Single-fiber bi-directional: 48 Ports Board, Two-fiber bi-directional: 24 Ports Board
P2P FE optical port OPGD/OPGE: Single-fiber bi-directional: 48 Ports Board, Two-fiber bi-directional: 24 Ports Board
Ethernet optical port ETHB: 8 Ports Board
E1 port H802EDTB: 16 Ports Board
ADSL2+ ADPD/ADPM/ADPE : 64 Ports Board
VDSL2 VDRD : 24 Ports Board
VDMF/VCMM : 48 Ports Board
VDPM/VDQM/VDPE/VDPD/VCPE : 64 Ports Board
EFM SHDSL SHLM : 16 Ports Board
SHGM : 32 Ports Board
TDM SHDSL H802EDTB: 16 Ports Board
POTS ASPB : 64 Ports Board
ADSL2+&POTS CAME : 48 Ports Board
VDSL2&POTS CVME : 48 Ports Board
CCPE : 64 Ports Board
ISDN BRA DSRD/DSRE :32 Ports Board
Power parameters
Power supply mode DC MPWC or AC MPWD 
Rated voltage DC power supply: -48 V / -60 V
AC power supply: 110 V / 220 V
Working voltage range DC power supply: -38.4 V to -72 V
AC power supply: 100 V to 240 V
Maximum input current DC power supply: 10 A
AC power supply: 6 A
Working environment temperature -40°C to +65°C
Working environment humidity 5% RH to 95% RH
Atmosphere pressure 61 kPa to 106 kPa
Altitude < 4000 m
Device Specifications
Dimensions (W x D x H, excluding mounting brackets) 442mm×244.5mm×88.1mm
Dimensions (W x D x H, including mounting brackets) 535mm×244.5mm×88.1mm, for ETSI cabinet 
NOTE:ETSI standard dimension is to add the ETSI mounting bracket on the IEC mounting bracket.
482.6mm×244.5mm×88.1mm, for IEC cabinet
Weight (empty chassis) 3.55KG

 

SmartAX MA5600T Series OLT

Item MA5600T(ETSI)/MA5680T MA5600T(IEC)/MA5680T MA5603T/MA5683T MA5608T
Supported cabinet Indoor cabinet: N63E-22, N66E-18 Indoor cabinet: N66E-22 Indoor cabinet: N66E-18 Indoor cabinet: N63E-22
Outdoor cabinet: F01D500, F01D2000 Outdoor cabinet: none Outdoor cabinet: F01D500, F01S300 Outdoor cabinet: F01S200
Board configuration 2 slots for control boards 2 slots for control boards 2 slots for control boards 2 slots for control boards
16 slots for service boards 14 slots for service boards 6 slots for service boards 2 slots for service boards
1 slot for the universal interface board 1 slot for the universal interface board 1 slot for the universal interface board 2 slots for the power interface board.
2 slots for upstream interface boards 2 slots for upstream interface boards 2 slots for upstream interface boards
2 slots for power interface boards. 2 slots for power interface boards. 2 slots for power interface boards.
Switching capacity of the backplane bus 3.2 Tbit/s 1.5 Tbit/s (H801MABO) 720 Gbit/s
2 Tbit/s (H802MABO)
Supported control board and its switching capacity SCUN: 480 Gbit/s in active/standby mode or 960 Gbit/s in load-sharing mode MCUD/MCUD1: 128 Gbit/s in active/standby mode or 256 Gbit/s in load-sharing mode
SCUH: 960 Gbit/s in active/standby mode or 1920 Gbit/s in load-sharing mode
SCUB: 48 Gbit/s
SCUF: 128 Gbit/s
System Layer 2 packet forwarding rate SCUN: 726 Mpps in active/standby mode or 1452 Mpps in load-sharing mode MCUD/MCUD1: 190 Mpps in active/standby mode or 380 Mpps in load-sharing mode
SCUH: 1428 Mpps in active/standby mode or 2856 Mpps in load-sharing mode
SCUB: 72 Mpps
SCUF: 190 Mpps
Switching/Forwarding delay Short forwarding delay: The 100 Mbit/s Ethernet port sends the 64-byte Ethernet packets at a delay shorter than 20 渭s.
BER in full load BER of a port when the port transmits data in full load < 10 e-7
System reliability specifications System: redundant configuration.
System availability for the typical configuration: > 99.999%
Mean time between failures (MTBF): about 45 years.
NOTE:
Due to different network environments and different boards used by devices, the preceding MTBF (45 years) of theMA5600T/MA5603T/MA5608Tis only for reference. The average repair time for field replaceable units (FRUs) is about 2 hours. The preceding values are only for reference. For details, contact the related Huawei engineers.
Maximum number of ADSL2+ ports in a subrack 1024 896 384 128
Maximum number of VDSL2 ports in a subrack 1024 896 384 128
Maximum number of EFM SHDSL ports in a subrack 512 448 192 64
Maximum number of TDM SHDSL ports in a subrack 256 224 96 32
Maximum number of POTS ports in a subrack 1024 896 384 128
Maximum number of ISDN BRA ports in a subrack 512 448 192 64
Maximum number of ISDN PRA ports in a subrack 64 56 64 64
Maximum number of GPON ports in a subrack 256 224 96 32
Maximum number of 10G GPON ports in a subrack 128 112 48 16
Maximum number of P2P FE ports in a subrack 768 672 288 96
Maximum number of P2P GE ports in a subrack 768 672 288 96
Maximum number of upstream ports (GE ports in the GIU slot) in a subrack 8 8 8 -
Maximum number of upstream ports (10GE ports in the GIU slot) in a subrack 4 4 4 -
Maximum number of upstream ports (PON ports in the GIU slot) in a subrack 2 (in the active/standby mode) 2 (in the active/standby mode) 2 -
Maximum number of upstream ports (ports on the control board) in a subrack SCUN/SCUK: 8 x GE (in the load-sharing mode) MCUD: 8 x GE (in the load-sharing mode)
SCUH: 8 x 10GE (in the load-sharing mode) MCUD1: 4 x GE + 2 x 10GE (in the load-sharing mode)
SCUB/SCUF: 4 x GE (in the active/standby mode)
Maximum number of extended subracks connected to a master subrack 32 32 32 -
Maximum number of ONUs supported by each subrack

For Layer 2 applications, the maximum number of ONUs supported by each subrack is determined based on the number of MAC addresses and service flows supported by the control board, as well as the number of MAC addresses and service flows planned for the ONUs.

For Layer 3 applications, the maximum number of ONUs supported by each subrack is determined based on the number of routes and ARP entries supported by the control board.

 Comparison of MA5600T Series OLT GPON service board

 

Specification H801GPBC H802GPBD H805GPBD H802GPFD/H805GPFD H806GPBH/H807GPBH H801GPMD
Port quantity 4 8 8 16 8 8
MAX Split ratio (Class B+) 1:64 1:64 1:64 1:64 1:64 1:64
MAX Split ratio (Class C+/Class C++) Not support 1: 128 1: 128 1: 128 1: 128 1: 128
D-CMTS No No No No No Yes
ONU-based shaping No No Yes Yes Yes Yes
Optical performance monitor Yes (querying Rx optical power is not supported) Yes Yes Yes Yes Yes
RSSI detection and controlled optical signal transmission of the optical module No Yes Yes Yes Yes Yes
ONU-based rate limitation ×
CAR group ×
Temperature query and high temperature alarm Yes Yes Yes Yes Yes Yes
Automatic power shutdown in case of a high temperature No Yes Yes Yes Yes Yes
Maximum differential fibre distance (km) 20 20 20 40 40 40
Maximum Number of Service Flows Supported by the Board 8184 8184 8184 16368 8184 6144
Maximum Number of MAC address Supported by the Board 32768 32768 32768 32768 32768 32768
Available DBA bandwidth (based on single port) (kbit/s) 1238400 1238784 1238784 1238784 1238784 1238784
Number of T-CONT supported by each GPON port 256 1024 1024 1024 1024 1024
Board supporting downstream FEC Yes Yes Yes Yes Yes Yes
Board supporting upstream FEC No Yes Yes Yes Yes Yes
Rogue ONT detection No Yes Yes Yes Yes Yes
Number of ONUs supported by a GPON port 64 128 128 128 128 128
Number of GEM ports supported by each board 8192 8192 8192 16384 8192 8192
Number of GEM ports supported by each GPON port 3872 3872 3872 3872 3872 3872
Number of service ports supported by each GEM port 8 8 8184 8184 8184 7168
HQoS (four levels) × × × H802GPFD: × H806GPBH: × ×
H805GPFD: √ H807GPBH: √
9216-byte Jumbo frames × × × H802GPFD: × H806GPBH: × ×
H805GPFD: √ H807GPBH: √
Power budget supported by a GPON port Class B+ (28.5 dB, mostly used) Class B+ (28.5 dB, mostly used),
Class C+ (32 dB long reach transmission)
Class C++: 35 dB
Minimum bandwidth supported by a T-CONT 512kbps 1 Mbit/s (in the minimum delay mode)
128 kbit/s (in the maximum bandwidth usage mode)

Huawei MA5608T belonging to Huawei SmartAX MA5600T series OLT products includes the MA5608TMA5683T, and MA5680T OLT in Huawei FTTH solution.

Huawei MA5608T OLT H801MABR subrack

Serves as the CO OLT and supports multiple network construction modes and diversified access media to provide access for home users, mobile users, and enterprise users

User access: provides access for home users, mobile users, and enterprise users

Network construction mode: supports FTTH, FTTB, FTTC, FTTW, FTTO, and FTTD networks

Access media: supports copper, fiber, cable, and Wi-Fi access

Supports aggregation management and plug-and-play for remote site, High-efficiency deployment, Fast integration and Easy OAM

Provides access for various traditional services, enabling a PSTN network seamlessly evolve to an IP network

Provides 3 protection mechanisms on the network side, access side, and device to ensure that services are not interrupted

Can be smoothly upgraded from GPON to 10G GPON by adding the WDM1r component

Specification
Backplane bus switching capacity 720 Gbit/s
System L2 packet forwarding rate MCUD/MCUD1: 190Mpps(Active/Standby mode), 380Mpps(Load-sharing mode)
Control board switching capacity MCUD/MCUD1: 128Gbit/s(Active/Standby mode),256Gbit/s(Load-sharing mode)
Switching/Forwarding delay Short forwarding delay: The 100 Mbit/s Ethernet port sends the 64-byte Ethernet packets at a delay shorter than 20 μs.
BER in full load BER of port when transmitting data in full load < 10 e-7
Configuration
Maintenance port Number of 10 Mbit/s/100 Mbit/s maintenance Ethernet ports: 1
Number of serial ports for local/remote maintenance: 1
Monitoring port Number of environment monitoring serial ports: 1
Maximum number of ADSL2+ ports in a subrack 128
Maximum number of VDSL2 ports in a subrack 128
Maximum number of EFM SHDSL ports in a subrack 64  NOTE: The MA5608T only supports the EFM SHDSL ports.
Maximum number of TDM SHDSL ports in a subrack 32
Maximum number of POTS ports in a subrack 128
Maximum number of ISDN BRA ports in a subrack 64
Maximum number of ISDN PRA ports in a subrack 64
Maximum number of GPON ports in a subrack 32
Maximum number of 10G GPON ports in a subrack 16
Maximum number of P2P FE ports in a subrack 96
Maximum number of P2P GE ports in a subrack 96
Management ports
Outband management Ethernet port (RJ-45) MCUD/MCUD1
Local serial port (Console) MCUD/MCUD1
Upstream ports
GE optical port MCUD1: 2 Ports Board
MCUD:4 Ports Board
ETHB/SPUF: 8 Ports Board
10GE optical port MCUD1: 2 Ports Board
SPUF: 8 Ports Board
E1 port TOPA: 16 Ports Board
STM-1 upstream optical port TOPA: 2 Ports Board
Service ports
GPON port GPBD/GPBH: 8 Ports Board
GPFD: 16 Ports Board
10G GPON port XGBC: 4 Ports Board
XGBD: 8 Ports Board
P2P GE optical port OPGD/OPGE: Single-fiber bi-directional: 48 Ports Board, Two-fiber bi-directional: 24 Ports Board
P2P FE optical port OPGD/OPGE: Single-fiber bi-directional: 48 Ports Board, Two-fiber bi-directional: 24 Ports Board
Ethernet optical port ETHB: 8 Ports Board
E1 port H802EDTB: 16 Ports Board
ADSL2+ ADPD/ADPM/ADPE : 64 Ports Board
VDSL2 VDRD : 24 Ports Board
VDMF/VCMM : 48 Ports Board
VDPM/VDQM/VDPE/VDPD/VCPE : 64 Ports Board
EFM SHDSL SHLM : 16 Ports Board
SHGM : 32 Ports Board
TDM SHDSL H802EDTB: 16 Ports Board
POTS ASPB : 64 Ports Board
ADSL2+&POTS CAME : 48 Ports Board
VDSL2&POTS CVME : 48 Ports Board
CCPE : 64 Ports Board
ISDN BRA DSRD/DSRE :32 Ports Board
Power parameters
Power supply mode DC MPWC or AC MPWD 
Rated voltage DC power supply: -48 V / -60 V
AC power supply: 110 V / 220 V
Working voltage range DC power supply: -38.4 V to -72 V
AC power supply: 100 V to 240 V
Maximum input current DC power supply: 10 A
AC power supply: 6 A
Working environment temperature -40°C to +65°C
Working environment humidity 5% RH to 95% RH
Atmosphere pressure 61 kPa to 106 kPa
Altitude < 4000 m
Device Specifications
Dimensions (W x D x H, excluding mounting brackets) 442mm×244.5mm×88.1mm
Dimensions (W x D x H, including mounting brackets) 535mm×244.5mm×88.1mm, for ETSI cabinet 
NOTE:ETSI standard dimension is to add the ETSI mounting bracket on the IEC mounting bracket.
482.6mm×244.5mm×88.1mm, for IEC cabinet
Weight (empty chassis) 3.55KG

 

SmartAX MA5600T Series OLT

Item MA5600T(ETSI)/MA5680T MA5600T(IEC)/MA5680T MA5603T/MA5683T MA5608T
Supported cabinet Indoor cabinet: N63E-22, N66E-18 Indoor cabinet: N66E-22 Indoor cabinet: N66E-18 Indoor cabinet: N63E-22
Outdoor cabinet: F01D500, F01D2000 Outdoor cabinet: none Outdoor cabinet: F01D500, F01S300 Outdoor cabinet: F01S200
Board configuration 2 slots for control boards 2 slots for control boards 2 slots for control boards 2 slots for control boards
16 slots for service boards 14 slots for service boards 6 slots for service boards 2 slots for service boards
1 slot for the universal interface board 1 slot for the universal interface board 1 slot for the universal interface board 2 slots for the power interface board.
2 slots for upstream interface boards 2 slots for upstream interface boards 2 slots for upstream interface boards
2 slots for power interface boards. 2 slots for power interface boards. 2 slots for power interface boards.
Switching capacity of the backplane bus 3.2 Tbit/s 1.5 Tbit/s (H801MABO) 720 Gbit/s
2 Tbit/s (H802MABO)
Supported control board and its switching capacity SCUN: 480 Gbit/s in active/standby mode or 960 Gbit/s in load-sharing mode MCUD/MCUD1: 128 Gbit/s in active/standby mode or 256 Gbit/s in load-sharing mode
SCUH: 960 Gbit/s in active/standby mode or 1920 Gbit/s in load-sharing mode
SCUB: 48 Gbit/s
SCUF: 128 Gbit/s
System Layer 2 packet forwarding rate SCUN: 726 Mpps in active/standby mode or 1452 Mpps in load-sharing mode MCUD/MCUD1: 190 Mpps in active/standby mode or 380 Mpps in load-sharing mode
SCUH: 1428 Mpps in active/standby mode or 2856 Mpps in load-sharing mode
SCUB: 72 Mpps
SCUF: 190 Mpps
Switching/Forwarding delay Short forwarding delay: The 100 Mbit/s Ethernet port sends the 64-byte Ethernet packets at a delay shorter than 20 渭s.
BER in full load BER of a port when the port transmits data in full load < 10 e-7
System reliability specifications System: redundant configuration.
System availability for the typical configuration: > 99.999%
Mean time between failures (MTBF): about 45 years.
NOTE:
Due to different network environments and different boards used by devices, the preceding MTBF (45 years) of theMA5600T/MA5603T/MA5608Tis only for reference. The average repair time for field replaceable units (FRUs) is about 2 hours. The preceding values are only for reference. For details, contact the related Huawei engineers.
Maximum number of ADSL2+ ports in a subrack 1024 896 384 128
Maximum number of VDSL2 ports in a subrack 1024 896 384 128
Maximum number of EFM SHDSL ports in a subrack 512 448 192 64
Maximum number of TDM SHDSL ports in a subrack 256 224 96 32
Maximum number of POTS ports in a subrack 1024 896 384 128
Maximum number of ISDN BRA ports in a subrack 512 448 192 64
Maximum number of ISDN PRA ports in a subrack 64 56 64 64
Maximum number of GPON ports in a subrack 256 224 96 32
Maximum number of 10G GPON ports in a subrack 128 112 48 16
Maximum number of P2P FE ports in a subrack 768 672 288 96
Maximum number of P2P GE ports in a subrack 768 672 288 96
Maximum number of upstream ports (GE ports in the GIU slot) in a subrack 8 8 8 -
Maximum number of upstream ports (10GE ports in the GIU slot) in a subrack 4 4 4 -
Maximum number of upstream ports (PON ports in the GIU slot) in a subrack 2 (in the active/standby mode) 2 (in the active/standby mode) 2 -
Maximum number of upstream ports (ports on the control board) in a subrack SCUN/SCUK: 8 x GE (in the load-sharing mode) MCUD: 8 x GE (in the load-sharing mode)
SCUH: 8 x 10GE (in the load-sharing mode) MCUD1: 4 x GE + 2 x 10GE (in the load-sharing mode)
SCUB/SCUF: 4 x GE (in the active/standby mode)
Maximum number of extended subracks connected to a master subrack 32 32 32 -
Maximum number of ONUs supported by each subrack

For Layer 2 applications, the maximum number of ONUs supported by each subrack is determined based on the number of MAC addresses and service flows supported by the control board, as well as the number of MAC addresses and service flows planned for the ONUs.

For Layer 3 applications, the maximum number of ONUs supported by each subrack is determined based on the number of routes and ARP entries supported by the control board.

 Comparison of MA5600T Series OLT GPON service board

 

Specification H801GPBC H802GPBD H805GPBD H802GPFD/H805GPFD H806GPBH/H807GPBH H801GPMD
Port quantity 4 8 8 16 8 8
MAX Split ratio (Class B+) 1:64 1:64 1:64 1:64 1:64 1:64
MAX Split ratio (Class C+/Class C++) Not support 1: 128 1: 128 1: 128 1: 128 1: 128
D-CMTS No No No No No Yes
ONU-based shaping No No Yes Yes Yes Yes
Optical performance monitor Yes (querying Rx optical power is not supported) Yes Yes Yes Yes Yes
RSSI detection and controlled optical signal transmission of the optical module No Yes Yes Yes Yes Yes
ONU-based rate limitation ×
CAR group ×
Temperature query and high temperature alarm Yes Yes Yes Yes Yes Yes
Automatic power shutdown in case of a high temperature No Yes Yes Yes Yes Yes
Maximum differential fibre distance (km) 20 20 20 40 40 40
Maximum Number of Service Flows Supported by the Board 8184 8184 8184 16368 8184 6144
Maximum Number of MAC address Supported by the Board 32768 32768 32768 32768 32768 32768
Available DBA bandwidth (based on single port) (kbit/s) 1238400 1238784 1238784 1238784 1238784 1238784
Number of T-CONT supported by each GPON port 256 1024 1024 1024 1024 1024
Board supporting downstream FEC Yes Yes Yes Yes Yes Yes
Board supporting upstream FEC No Yes Yes Yes Yes Yes
Rogue ONT detection No Yes Yes Yes Yes Yes
Number of ONUs supported by a GPON port 64 128 128 128 128 128
Number of GEM ports supported by each board 8192 8192 8192 16384 8192 8192
Number of GEM ports supported by each GPON port 3872 3872 3872 3872 3872 3872
Number of service ports supported by each GEM port 8 8 8184 8184 8184 7168
HQoS (four levels) × × × H802GPFD: × H806GPBH: × ×
H805GPFD: √ H807GPBH: √
9216-byte Jumbo frames × × × H802GPFD: × H806GPBH: × ×
H805GPFD: √ H807GPBH: √
Power budget supported by a GPON port Class B+ (28.5 dB, mostly used) Class B+ (28.5 dB, mostly used),
Class C+ (32 dB long reach transmission)
Class C++: 35 dB
Minimum bandwidth supported by a T-CONT 512kbps 1 Mbit/s (in the minimum delay mode)
128 kbit/s (in the maximum bandwidth usage mode)

GLOBAL SHIPPING
XponShop offers you various options of shipping ways:
-EXW SHENZHEN
-Overseas Express which includes shipping by Carriers, by Air Cargo, and Sea Freight.

Cargo Weight/Volume Suggested Shipping Ways Comments
≤ 45KGS By Shipping Carriers (DHL, UPS, FedEx, etc.) Door to door service, fast and convenient.
>45KGS By Air Cargo Door to airport service, more cost-efficient.
1CBM By Sea Freight Large-volume goods, door to seaport service, longer shipping time but cheaper.

XponShop makes the most commonly used trade terms available for your convenience: CNF, CPT, CIF, DDP, etc to ensure global fast and convenient delivery.
Once you confirm your order, you may contact XponShop team for calculating the freight charges and choose the optimal shipping way.
NOTE:
· Shipping may be subject to local taxes or duties; XponShop is not responsible for and has no control over these charges.
· No matter which shipping ways you chose, cargo insurance is highly recommended in case of unpredictable loss.

RETURN POLICY
We aim to deliver products for your appreciation and satisfaction. XponShop return or replacement policy applies only if the product is damaged or incorrectly delivered.
–If you receive a damaged product or it is different from the one requested, you can return or replace it within 7 days of receipt. In such a case, costs shall be borne by XponShop.
–If the product is malfunctional during use and under 12 months warranty, XponShop support team will contact you to troubleshoot the issue by professional diagnosis. The unsolvable problem will trigger the return procedure: repair, replace and reship to you or refund if repair or replacement is inapplicable.
NOTE:
· Please be aware that the product must be returned to the specified address as defined by shipping incoterms against the sales invoice/contract.
· For further information about how to return products, please contact our XponShop team at sales@xponshop.com, we will advise you on how to proceed.

Customer Reviews

Based on 7 reviews
71%
(5)
0%
(0)
29%
(2)
0%
(0)
0%
(0)
M
Mia
Suitable for the rural less-dense areas.

This small OLT delivers big results. The 32-port GPON capability is perfect for our rural deployments.

C
C.
Shipping is not good.

We met problem during the customs clearance, the cargo arrived delay.

M
Minwyelet
Recommended!

When we have any questions, XPONSHOP team demonstrates very professional technical service.

B
Bernard
¡Bien!

Acabamos de probar la caja OLT ma5608t, todo está bien.

E
Elijah
Perfect!

Thanks as always for your prompt response and outstanding customer service.